Our comprehensive syringe driver awareness training course is ideal for registered nurses who require a refresher course on syringe drivers. Bd vacutainer safety lok blood set 23g x 7 tubing x 25. Staff should only use this equipment if trained to do so. Swinglock clamp 0,01 minimum increments instead of 0,1 mlh is activated when the max patient weight is set to 20 kg in the drug library. The priming volume of iv administration sets vary by manufacturer and affected by the length of the tubing and any addon devices. If the purge syringe option has been enabled then the prompt to purge screen is displayed and the set can be purged as required. Mukoreka j, sisay i 2015 safe practice in syringe pump. Safe practice in syringe pump management nursing times.
Bd saftintima has a telescoping needle shield which completely covers the needle as it is withdrawn, reducing the risk of needle stick injuries. Attach giving set firmly to the syringe ensure secure connection. When and how to use a syringe driver in palliative care. Description related products 1 pack20 replacement for 100172s click here for close alternative pa100v.
This is because the niki t34 syringe driver simplifies administration by detecting the syringe size and volume of medicine, and sets the rate to deliver the infusion over the required time period, e. Check the infusion rate with the new syringe as before. The patient uses an elastomeric pump or a batterydriven, syringe driver infusion pump to deliver a specified continuous amount of desferal subcutaneously over a selfadministered period. This can be achieved in numerous ways, from a simple repeated bolus to administering the drug within a carrier fluid such as crystalloid solutions by giving set or fluid pump, to the most reliable and accurate method. The priming volume information can be found on the packaging label of the iv. To deliver apomorphine, the patient inserts an infusion set under the skin and connects it to the infusion pump. Infusion rate change rate if necessary using the f keys. Cme medical offer an array of products, from syringe drivers and accessories to bodyguard volumetric pumps and iv safety connectors. Syringe drivers continuous subcutaneous infusion marie curie. The syringe driver pump is able to deliver a combination of medications and does so. In addition, an increase in indwell times reduces overall costs of catheter materials and staff time improved patient and clinician safety from nsi.
Gp supplies is the uks premier online store for medical supplies. After the iv bag is spiked with the iv administration set, the iv solutionfluid flows through the tubing to remove the air. You might be offered a syringe driver if you cannot take medicine by mouth for example, if youre being sick. September 2018 page 4 of 31 palliative care department 2. A syringe driver is a portable battery powered device that administers medication subcutaneously over a chosen period of time. The syringe should be measured every time the device is set up, as different brands of syringes have different diameters and lengths9. Diazepam, chlorpromazine and prochlorperazine are too. T34 syringe driver instruction video for oxfordshire youtube. The cme t34 ambulatory syringe driver is a portable, battery operated device for delivering medication by continuous subcutaneous infusion csci, which.
The pump holds a syringe containing medication and this is connected to the patient via a small needle and a line. Practice guidance proposes that if a patient then requires regular doses, it is more effective and less intrusive to administer medication slowly and continuously over a 24 h period via a syringe driver pump. When autoplay is enabled, a suggested video will automatically. Flow rate can be limited according to drug name soft and hard limits with agilia vigilant druglib, iv medication safety system. The patient needs to change the infusion set at least. A maximum of 3 compatible drugs can be mixed in a syringe for administration via this route. We aimed to define the variation in drug delivery seen in three syringe drivers, with changes in relative height between the syringe driver and the end of the giving set. Sometimes a small batteryoperated pump called a syringe driver is used to give medicine continuously under the skin for a period of time, such as 24 hours. Effect of infusion pump height on drug delivery rate. Ensure extension set is attached to syringe, but disconnected from patient. It works with the alaris pc unit and combines precision instrumentation with bd alaris guardrails suite mx software to help ensure accurate medication delivery.
Introduction this protocol covers all inpatient and community services within harrogate and district nhs foundation trust hdft. Braun space is a modular infusion system that is small, light, and easy to use. The lockable, battery operated, niki t34 syringe driver is the current device available in new zealand for the. A range of infusion devices including volumetric pumps and syringe drivers.
This video will describe how to use the saftintima 24 gauge subcutaneous needle by bd canada. Syringe drivers are often used at the end of life because they are the easiest way to give someone the medicines they need to feel comfortable at that time. They are a safe and effective way to give medicines for symptoms such as pain, nausea and vomiting, seizures, agitation and respiratory secretions. An aseptic technique should be used when preparing and setting. The infusion sets should be changed with every treatment. Administering anticipatory medications in endoflife care.
Remove the empty syringe from the driver by loosening the rubber strip and sliding back the mechanism. Sets include safety clip for freeflow protection and standard, lueractivated needlefree, or suresite prepierced injection sites filter sets. The t34 provides safe and simple administration of medication, in both hospital and homecare environments. Setting up a t34 syringe driver lock on prime and load when setting up a syringe driver or renewing the next 24 hour syringe, two qualified nurses should check the drugs, the rate and the identity of the patient 1 initial set up. The course will teach theoretical and practical skills related to the safe and effective use of syringe drivers as well as the importance of correct machine set up. Guidelines for syringe driver management in palliative care. Syringe pumps also known as syringe drivers are commonly used for people living with a terminal illness. The syringe driver describes how syringe drivers allow for a single or mixture of compatible medications to be delivered by syringe rather than by infusion bag. One part of the yarm can be connected to a syringe driver or infusion pump. The infusomat space volumetric pump and the perfusor space syringe pump are the basic building blocks of the space system. Your doctor or specialist nurse will prescribe the medicines that will best manage your symptoms. He obviously has trouble swallowing his morphine tablet and anti sickness tablet so as of 4 days ago he had a syringe driver fitted. Three syringe drivers alaris cc, perfusor space, and synamed.
Extension set bore micro pvc for t34 syringe driver 100cm set anti siphon 0. Setting up a cme medical t34 syringe driver oxfordshire ccg. Volumetric iv specialty sets, infusion smiths medical. A syringe containing medication is attached to the driver, which pushes the plunger forward at a controlled rate. A syringe driver takes 34 hours to establish a steady state drug level in plasma. T34 adult syringe driver guidelines harrogate and rural. They can be used in hospital, in hospices and at home. The same brand of syringe should be used each time to minimise errors in setting up the syringe driver and calculating the rate6, 9. If the patient is in pain, vomiting or very agitated, give a stat sc injection of appropriate medication while setting up the syringe driver.
Clinical protocol for the use of syringe drivers in palliative care patients. This must always be done to safeguard against errors even if the syringe has been made to the same volume. The patient uses a batterydriven, syringe driver infusion pump to deliver a specified continuous amount of the drug when required, adjusting the amount as needed during the day. My dad was diagnosed with terminal oesophageal cancer with secondary mets in his lungs and liver on 23rd december. The patient inserts an infusion set under the skin and connects it to the infusion pump. Guidelines for setting up and changing the mckinley t34 syringe driver for children receiving palliative care. Adsorption when a drug in solution binds to the surface of its container, giving set or inline filter reduces the amount of drug available to be administered to the patient. T34 ambulatory syringe pump is a lightweight, compact and fully ambulatory syringe pump with motor driven linear actuator, pulsed motion. The mckinley t34 syringe pump is preset for 24hour delivery and is calibrated in millilitres. The alaris syringe module is intended for the delivery of fluids, medications, blood and blood products using continuous or intermittent delivery. Our range includes medical disposables, medical equipment, pharmaceuticals, surgical nursing and first aid equipment from leading brands like instrapac, instramed, instraspec, comfispec, keeler, welch allyn, omron, smith and nephew, ecolab, clinell and many more. A syringe driver is a small battery operated pump designed to deliver medication sub cutaneously just under the skin over a 24 hour period. Only use drugs that are known to be effective via the sc route. Its common to feel nervous about having a syringe driver but most people find that they are very helpful for managing symptoms and give a feeling of reassurance.